Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Heart Lung Circ ; 30(1): 78-85, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32896482

RESUMO

BACKGROUND: Spontaneous coronary artery dissection (SCAD) is an important but under-recognised cause of acute coronary syndrome (ACS), particularly in younger women. We assessed trends in the detection, management and outcomes of all patients with SCAD over 6 consecutive years. METHODS: All patients with first diagnosis of SCAD at Christchurch Public Hospital, New Zealand, between January 2014 and January 2020 were included. Patient management and outcomes were determined by retrospective review of medical records. SCAD presentations were compared to total ACS presentations, obtained from a national ACS (ANZACS-QI) database. RESULTS: We identified 113 patients with angiographic diagnosis of SCAD. Median age was 54 years (88% female). The detection of SCAD increased over the period, both as a total number (Kendall's τ 0.87, p=0.015) and as a proportion of all ACS (p value for trend <0.0001). In 2019, SCAD represented 2.4% of all ACS and 18% of ACS in females aged less than 60 years. The most common presentation was non-ST elevation myocardial infarction (NSTEMI) in 72%; and, there was an increase in NSTEMI compared with STEMI over the period (p=0.023). Initial strategy of percutaneous coronary intervention (PCI) was undertaken in 12% of patients, with a significant trend towards a more conservative approach over the study period (p=0.019). The rate of 30-day major adverse cardiovascular events (MACE) was 8.8% overall, and significantly reduced over the study period to 3% in 2019 (p value for trend, 0.006). CONCLUSIONS: The detection of SCAD has increased and is a particularly important cause of ACS in younger women. This increase has been largely driven by an increasing number of NSTEMI patients diagnosed with SCAD, associated with a significant improvement in 30-day MACE.


Assuntos
Anomalias dos Vasos Coronários/cirurgia , Vasos Coronários/cirurgia , Intervenção Coronária Percutânea/métodos , Doenças Vasculares/congênito , Idoso , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/epidemiologia , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Nova Zelândia/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Doenças Vasculares/diagnóstico , Doenças Vasculares/epidemiologia , Doenças Vasculares/cirurgia
2.
PLoS One ; 13(3): e0192952, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29590135

RESUMO

Myeloperoxidase (MPO)-derived oxidants have emerged as a key contributor to tissue damage in inflammatory conditions such as cardiovascular disease. Pro-myeloperoxidase (pro-MPO), an enzymatically active precursor of myeloperoxidase (MPO), is known to be secreted from cultured bone marrow and promyelocytic leukemia cells, but evidence for the presence of pro-MPO in circulation is lacking. In the present study, we used a LC-MS/MS in addition to immunoblot analyses to show that pro-MPO is present in human blood plasma. Furthermore, we found that pro-MPO was more frequently detected in plasma from patients with myocardial infarction compared to plasma from control donors. Our study suggests that in addition to mature MPO, circulating pro-MPO may cause oxidative modifications of proteins thereby contributing to cardiovascular disease.


Assuntos
Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/enzimologia , Precursores Enzimáticos/sangue , Peroxidase/sangue , Sequência de Aminoácidos , Animais , Células CHO , Doenças Cardiovasculares/metabolismo , Cricetinae , Cricetulus , Células HL-60 , Halogenação , Humanos , Immunoblotting , Infarto do Miocárdio/sangue , Infarto do Miocárdio/enzimologia , Infarto do Miocárdio/metabolismo , Oxirredução , Coelhos
3.
Heart Lung Circ ; 27(2): 212-218, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28652031

RESUMO

BACKGROUND: Adenosine induced hyperaemic fractional flow reserve (aFFR) is a validated predictor of clinical outcome and part of routine interventional practice. Protocol issues associated with the adenosine infusion limit the use of aFFR in clinical practice. Contrast medium induced hyperaemic FFR (cFFR) is a simpler procedure from a practical standpoint. We compared the two in a real world setting. METHODS: We analysed 76 patients that had both cFFR and aFFR assessment of 100 angiographically indeterminate coronary stenosis. cFFR was performed with intracoronary contrast medium injections (10ml for left coronary lesions and 8ml for right coronary lesions). The diagnostic performance of cFFR was analysed and compared to the gold standard aFFR. RESULTS: Mean cFFR was 0.87 (±0.07) and mean aFFR was 0.84 (±0.08). Bland-Altman analysis revealed a close agreement between cFFR and aFFR (0.035±0.032; 95% CI: -0.028 to 0.098) and good linear correlation (r=0.92, r2=0.86; p<0.0001). Using cFFR cut-off values of ≤0.83 in predicting an aFFR value of ≤0.80 or a cFFR value ≥0.88, predicting an aFFR value of >0.80 yielded a sensitivity of 100%, specificity of 96.1%, positive predictive value of 92.3%, negative predictive value of 100% and diagnostic accuracy of 96%. Only 24% of cFFR values were in the 0.84 to 0.87 range. CONCLUSION: Contrast medium induced hyperaemic FFR as an initial assessment may limit the need for adenosine to when cFFR falls in the 0.84 to 0.87 range. The use of adenosine infusion potentially could have been avoided in the majority of patients in this study.


Assuntos
Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Meios de Contraste/farmacologia , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC
4.
JACC Cardiovasc Imaging ; 11(5): 722-732, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28734923

RESUMO

OBJECTIVES: The purpose of this study was to assess the diagnostic accuracy of coronary computed tomography angiography (CTA) for bioresorbable vascular scaffold (BVS) evaluation. BACKGROUND: Coronary CTA has emerged as a noninvasive method to evaluate patients with suspected or established coronary artery disease. The diagnostic accuracy of coronary CTA to evaluate angiographic outcomes after BVS implantation has not been well established. METHODS: In the ABSORB II (A Bioresorbable Everolimus-Eluting Scaffold Versus a Metallic Everolimus-Eluting Stent II) study, patients were randomized either to receive treatment with the BVS or everolimus-eluting metallic stent. At the 3-year follow-up, 238 patients (258 lesions) treated with BVS underwent coronary angiography with intravascular ultrasound (IVUS) evaluation and coronary CTA. The diagnostic accuracy of coronary CTA was assessed by the area under the receiver-operating characteristic curve with coronary angiography and IVUS as references. RESULTS: The mean difference in coronary CTA-derived minimal luminal diameter was -0.14 mm (limits of agreement -0.88 to 0.60) with quantitative coronary angiography as reference, whereas the mean difference in minimal lumen area was 0.73 mm2 (limits of agreement -1.85 to 3.30) with IVUS as reference. The per-scaffold diagnostic accuracy of coronary CTA for detecting stenosis based on coronary angiography diameter stenosis of ≥50% revealed an area under the receiver-operating characteristic curve of 0.88 (95% confidence interval [CI]: 0.82 to 0.92) with a sensitivity of 80% (95% CI: 28% to 99%) and a specificity of 100% (95% CI: 98% to 100%), whereas diagnostic accuracy based on IVUS minimal lumen area ≤2.5 mm2 showed an area under the receiver-operating characteristic curve of 0.83 (95% CI: 0.77 to 0.88) with a sensitivity of 71% (95% CI: 44% to 90%) and a specificity of 82% (95% CI: 75% to 87%). The diagnostic accuracy of coronary CTA was similar to coronary angiography in its ability to identify patients with a significant lesion based on the IVUS criteria (p = 0.75). CONCLUSIONS: Coronary CTA has good diagnostic accuracy to detect in-scaffold luminal obstruction and to assess luminal dimensions after BVS implantation. Coronary angiography and coronary CTA yielded similar diagnostic accuracy to identify the presence and severity of obstructive disease. Coronary CTA might become the method of choice for the evaluation of patients treated with BVS.


Assuntos
Implantes Absorvíveis , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Intervenção Coronária Percutânea/instrumentação , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Método Simples-Cego , Resultado do Tratamento , Ultrassonografia de Intervenção
5.
Circ Cardiovasc Interv ; 10(9)2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28893770

RESUMO

BACKGROUND: The long-term fate of Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, CA) struts jailing side branch ostia has not been clarified. We therefore evaluate serially (post-procedure and at 6 months, 1, 2, 3, and 5 years) the appearance and fate of jailed Absorb bioresorbable vascular scaffold struts. METHODS AND RESULTS: We performed 3-dimensional optical coherence tomographic analysis of the ABSORB Cohort B trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) up to 5 years using a novel, validated cut-plane analysis method. We included 29 patients with a total of 85 side branch ostia. From the 12 ostia which could be assessed in true serial fashion, 7 showed a pattern of initial decrease in the ostial area free from struts, followed by an increase in strut-free ostial area toward the end of the 5 years of follow-up. In a repeated-measures analysis with time as fixed variable and ostial area free from struts as dependent variable, we showed a numeric decrease in the estimated ostial area free from struts from 0.75 mm2 (baseline) to 0.68 mm2 (first follow-up visit at 6 months or 1 year) and 0.63 mm2 (second follow-up visit at 2 or 3 years). However, from the second visit to the 5-year follow-up visit, there was a statistically significant increase from 0.63 to 0.89 mm2 (P=0.001). Struts overlying an ostium divided the ostium into compartments, and the number of these compartments decreased over time. CONCLUSIONS: This study showed that in most cases, the side branch ostial area free from struts initially decreased. However, with full scaffold bioresorption, the ostial area free from scaffold increased between 2 to 3 years and 5 years in the vast majority of patients. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00856856.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Fármacos Cardiovasculares/efeitos adversos , Everolimo/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
6.
Eur Heart J Cardiovasc Imaging ; 18(8): 870-879, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28329198

RESUMO

AIMS: Multimodality invasive imaging of the first-in-man cohort demonstrated at 5 years stable lumen dimensions and a low rate of major adverse cardiac events (MACE). However, the long-term non-invasive assessment of this device remains to be documented. The objective was to describe the 72-month multislice computed tomography (MSCT) angiographic and functional findings after the implantation of the second iteration of the fully resorbable everolimus-eluting polymeric scaffold. METHODS AND RESULTS: In the ABSORB Cohort B trial patients with non-complex de novo lesions were treated with second iteration bioresobable vascular scaffold (BVS). MSCT angiography was performed as an optional investigation at 18 months; patients were reconsented for a second investigation at 72 months. MSCT data were analysed at independent core laboratories for quantitative analysis of lumen dimensions and for calculation of fractional flow reserve derived from computed tomography (FFRCT). From the overall Cohort B (101 patients), 53 patients underwent MSCT imaging at 72 months. The MACE rate was 1.9% (1/53). At 72 months, the median minimal lumen area (MLA) was 4.05 mm2 (interquartile range [IQR]: 3.15-4.90) and the mean percentage area stenosis was 18% (IQR: 4.75-31.25), one scaffold was totally occluded. In 39 patients with paired MSCT analysis, the MLA significantly increased from the first to the second follow-up (Δ = 0.80 mm2, P = 0.002). The change in the median FFRCT scaffold gradient between time points was zero. CONCLUSION: The long-term serial non-invasive MSCT evaluation with FFRCT assessment after bioresorbable scaffold implantation confirmed in-scaffold late lumen enlargement with the persistence of normalization of the FFRCT. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00856856.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Stents Farmacológicos , Everolimo/farmacologia , Tomografia Computadorizada Multidetectores/métodos , Implantes Absorvíveis , Idoso , Feminino , Seguimentos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Medição de Risco , Estatísticas não Paramétricas , Fatores de Tempo , Alicerces Teciduais , Resultado do Tratamento
7.
JACC Cardiovasc Imaging ; 10(10 Pt A): 1151-1161, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28330651

RESUMO

OBJECTIVES: The aim of this study was to assess calcium growth with fused grayscale intravascular ultrasound (IVUS), IVUS-virtual histology, and optical coherence tomography (OCT) from baseline to 5-year follow-up in patients treated with bioresorbable vascular scaffolds. BACKGROUND: IVUS and OCT have individual strengths in assessing plaque composition and volume. Fusion of images obtained using these methods could potentially aid in coronary plaque assessment. METHODS: Anatomic landmarks and endoluminal radiopaque markers were used to fuse OCT and IVUS images and match baseline and follow-up. RESULTS: Seventy-two IVUS-virtual histology and OCT paired matched cross-sectional in- and out-scaffold segments were fused at baseline and follow-up. In total, 46 calcified plaques at follow-up were detected using the fusion method (33 in-scaffold, 13 out-scaffold), showing either calcium progression (52.2%) or de novo calcifications (47.8%). On OCT, calcification volume increased from baseline to follow-up by 2.3 ± 2.4 mm3 (p = 0.001). The baseline virtual histologic tissue precursors of dense calcium at follow-up were necrotic core in 73.9% and fibrous or fibrofatty plaque in 10.9%. In 15.2%, calcium was already present at baseline. Precursors on OCT were lipid pool in 71.2%, fibrous plaque in 4.3%, and fibrocalcific plaque in 23.9%. CONCLUSIONS: The use of OCT and IVUS fusion imaging shows similar calcium growth in- and out-scaffold segments. Necrotic core is the most frequent precursor of calcification. The scaffold resorption process creates a tissue layer that re-caps the calcified plaques. (Absorb Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Imagem Multimodal/métodos , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Idoso , Progressão da Doença , Feminino , Fibrose , Seguimentos , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Necrose , Intervenção Coronária Percutânea/efeitos adversos , Placa Aterosclerótica , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
8.
Lancet ; 388(10059): 2479-2491, 2016 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-27806897

RESUMO

BACKGROUND: No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a result of recovered vasomotion of the scaffolded vessel. METHODS: The ABSORB II trial is a prospective, randomised, active-controlled, single-blind, parallel two-group, multicentre clinical trial. We enrolled eligible patients aged 18-85 years with evidence of myocardial ischaemia and one or two de-novo native lesions in different epicardial vessels. We randomly assigned patients (2:1) to receive treatment with an everolimus-eluting bioresorbable scaffold (Absorb; Abbott Vascular, Santa Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (Xience; Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetes status and number of planned target lesions. At 3 year follow-up, the primary endpoint was superiority of the Absorb bioresorbable scaffold versus the Xience metallic stent in angiographic vasomotor reactivity after administration of intracoronary nitrate. The co-primary endpoint is the non-inferiority of angiographic late luminal loss. For the endpoint of vasomotion, the comparison was tested using a two-sided t test. For the endpoint of late luminal loss, non-inferiority was tested using a one-sided asymptotic test, against a non-inferiority margin of 0·14 mm. The trial is registered at ClinicalTrials.gov, number NCT01425281. FINDINGS: Between Nov 28, 2011, and June 4, 2013, we enrolled 501 patients and randomly assigned them to the Absorb group (335 patients, 364 lesions) or the Xience group (166 patients, 182 lesions). The vasomotor reactivity at 3 years was not statistically different (Absorb group 0·047 mm [SD 0·109] vs Xience group 0·056 mm [0·117]; psuperiority=0·49), whereas the late luminal loss was larger in the Absorb group than in the Xience group (0·37 mm [0·45] vs 0·25 mm [0·25]; pnon-inferiority=0·78). This difference in luminal dimension was confirmed by intravascular ultrasound assessment of the minimum lumen area (4·32 mm2 [SD 1·48] vs 5·38 mm2 [1·51]; p<0·0001). The secondary endpoints of patient-oriented composite endpoint, Seattle Angina Questionnaire score, and exercise testing were not statistically different in both groups. However, a device-oriented composite endpoint was significantly different between the Absorb group and the Xience group (10% vs 5%, hazard ratio 2·17 [95% CI 1·01-4·70]; log-rank test p=0·0425), mainly driven by target vessel myocardial infarction (6% vs 1%; p=0·0108), including peri-procedural myocardial infarction (4% vs 1%; p=0·16). INTERPRETATION: The trial did not meet its co-primary endpoints of superior vasomotor reactivity and non-inferior late luminal loss for the Absorb bioresorbable scaffold with respect to the metallic stent, which was found to have significantly lower late luminal loss than the Absorb scaffold. A higher rate of device-oriented composite endpoint due to target vessel myocardial infarction, including peri-procedural myocardial infarction, was observed in the Absorb group. The patient-oriented composite endpoint, anginal status, and exercise testing, were not statistically different between both devices at 3 years. Future studies should investigate the clinical impact of accurate intravascular imaging in sizing the device and in optimising the scaffold implantation. The benefit and need for prolonged dual antiplatelet therapy after bioresorbable scaffold implantation could also become a topic for future clinical research. FUNDING: Abbott Vascular.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis/uso terapêutico , Estenose Coronária/tratamento farmacológico , Stents Farmacológicos/estatística & dados numéricos , Everolimo , Imunossupressores/uso terapêutico , Stents Metálicos Autoexpansíveis/estatística & dados numéricos , Estenose Coronária/cirurgia , Humanos , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/cirurgia , Método Simples-Cego , Resultado do Tratamento , Ultrassonografia de Intervenção
9.
Int J Cardiol ; 222: 832-840, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27522385

RESUMO

BACKGROUND & AIMS: Although Absorb Bioresorbable Vascular Scaffolds (A-BVS) are routinely used in the Asia-Pacific, there is little information on patient selection or deployment technique here. This document investigates the experiences of leading interventional cardiologists from the Asia-Pacific region with a focus on patient characteristics, deployment techniques and management. METHODS AND RESULTS: A detailed questionnaire was distributed to 28 highly-experienced interventional cardiologists ('Authors') from 13 Asia-Pacific countries. The results were discussed at a meeting on patient selection, technical consideration, deployment practices and patient management. Potential patient benefits of Absorb compared to metallic DES, the learning curve for patient selection and preparation, device deployment, and subsequent patient management approaches are presented. CONCLUSIONS: Current practices are derived from guidelines optimized for European patients. Differences in approach exist in the Asia-Pacific context, including limited access to imaging and frequency of occurrence of complex lesions. Nevertheless, the use of the Absorb BVS ('Absorb') in certain Asia-Pacific countries has flourished and practices here are continuing to mature.


Assuntos
Implantes Absorvíveis/estatística & dados numéricos , Prótese Vascular/estatística & dados numéricos , Cardiologistas/estatística & dados numéricos , Cardiologia , Doença da Artéria Coronariana/cirurgia , Alicerces Teciduais/estatística & dados numéricos , Ásia , Humanos , Desenho de Prótese
10.
J Am Coll Cardiol ; 67(7): 766-76, 2016 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-26892411

RESUMO

BACKGROUND: Long-term benefits of coronary stenosis treatment with an everolimus-eluting bioresorbable scaffold are unknown. OBJECTIVES: This study sought to evaluate clinical and imaging outcomes 5 years after bioresorbable scaffold implantation. METHODS: In the ABSORB multicenter, single-arm trial, 45 (B1) and 56 patients (B2) underwent coronary angiography, intravascular ultrasound (IVUS), and optical coherence tomography (OCT) at different times. At 5 years, 53 patients without target lesion revascularization underwent final imaging. RESULTS: Between 6 months/1 year and 5 years, angiographic luminal late loss remained unchanged (B1: 0.14 ± 19 mm vs. 0.13 ± 0.33 mm; p = 0.7953; B2: 0.23 ± 0.28 mm vs. 0.18 ± 0.32 mm; p = 0.5685). When patients with a target lesion revascularization were included, luminal late loss was 0.15 ± 0.20 mm versus 0.15 ± 0.24 mm (p = 0.8275) for B1 and 0.30 ± 0.37 mm versus 0.32 ± 0.48 mm (p = 0.8204) for B2. At 5 years, in-scaffold and -segment binary restenosis was 7.8% (5 of 64) and 12.5% (8 of 64). On IVUS, the minimum lumen area of B1 decreased from 5.23 ± 0.97 mm(2) at 6 months to 4.89 ± 1.81 mm(2) at 5 years (p = 0.04), but remained unchanged in B2 (4.95 ± 0.91 mm(2) at 1 year to 4.84 ± 1.28 mm(2) at 5 years; p = 0.5). At 5 years, struts were no longer discernable by OCT and IVUS. On OCT, the minimum lumen area in B1 decreased from 4.51 ± 1.28 mm(2) at 6 months to 3.65 ± 1.39 mm(2) at 5 years (p = 0.01), but remained unchanged in B2, 4.35 ± 1.09 mm(2) at 1 year and 4.12 ± 1.38 mm(2) at 5 years (p = 0.24). Overall, the 5-year major adverse cardiac event rate was 11.0%, without any scaffold thrombosis. CONCLUSIONS: At 5 years, bioresorbable scaffold implantation in a simple stenotic lesion resulted in stable lumen dimensions and low restenosis and major adverse cardiac event rates. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).


Assuntos
Implantes Absorvíveis , Estenose Coronária/cirurgia , Stents Farmacológicos , Everolimo/farmacologia , Poliésteres , Alicerces Teciduais , Idoso , Causas de Morte/tendências , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/mortalidade , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Taxa de Sobrevida/tendências , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
11.
EuroIntervention ; 12(3): 352-5, 2016 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-26403639

RESUMO

AIMS: Our aim was to evaluate the two-year clinical results of a new sirolimus-eluting stent (MiStent SES) with a bioabsorbable coating designed for rapid polymer dissolution but sustained drug delivery. METHODS AND RESULTS: Major adverse cardiac events (MACE), target lesion failure (TLF), target vessel failure (TVF), and stent thrombosis (ST) at two-year follow-up are reported for the DESSOLVE I and II trials. In DESSOLVE I, the MiStent SES (n=29) demonstrated a 3.4% two-year MACE rate without TLF or TVF. In DESSOLVE II, the MiStent group had a 6.7% (8/120) two-year MACE rate compared to 13.3% (8/60) for Endeavor (p=0.167). TLF was 5.0% in the MiStent and Endeavor groups (p=1.00). TVF was 5.0% for MiStent versus 11.7% for Endeavor (p=0.129). No probable or definite ST was reported with the MiStent up to two years. The median duration of dual antiplatelet therapy (DAPT) in DESSOLVE I and II was 364 and 366 days, respectively. CONCLUSIONS: The MiStent SES demonstrated good long-term safety and effectiveness with low two-year MACE, TLF, and TVF rates.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Sirolimo/uso terapêutico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Polímeros/administração & dosagem , Polímeros/uso terapêutico , Sirolimo/administração & dosagem , Solubilidade , Tempo , Resultado do Tratamento
12.
JACC Cardiovasc Interv ; 8(8): 1053-1063, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26205444

RESUMO

OBJECTIVES: This study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation. BACKGROUND: A fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence of periprocedural myocardial injury. METHODS: In 501 patients with stable or unstable angina randomized to either Absorb (335 patients) or EES (n = 166) in the ABSORB II trial, 3 types of CB (creatine kinase, creatine kinase-myocardial band, and troponin) were obtained before and after procedure. Per protocol, periprocedural myocardial infarction (PMI) was defined as creatine kinase rise >2× the upper limit of normal with creatine kinase-myocardial band rise. RESULTS: Incidence of side branch occlusion and any anatomic complications assessed by angiography was similar between the 2 treatment arms (side branch occlusion: Absorb: 5.3% vs. Xience: 7.6%, p = 0.07; any anatomic complication: Absorb: 16.4% vs. EES: 19.9%, p = 0.39). Fourteen patients who presented with recent myocardial infarction at entry with normalized creatine kinase-myocardial band according to the protocol were excluded for post-CB analysis. The overall compliance for CB was 97.8%. The CB rise subcategorized in 7 different ranges was comparable between the 2 treatment arms. PMI rate was numerically higher in the Absorb arm according to the per-protocol definitions, and treatment with overlapping devices was the only independent determinant of per-protocol PMI (odds ratio: 5.07, 95% confidence interval: 1.78 to 14.41, p = 0.002). CONCLUSIONS: There were no differences in the incidence of CB rise and PMI between Absorb and EES. Device overlap might be a precipitating factor of myocardial injury. (ABSORB II Randomized Clinical Trial: A Clinical Evaluation to Compare the Safety, Efficacy, and Performance of Absorb Everolimus Eluting Bioresorbable Vascular Scaffold System Against Xience Everolimus Eluting Coronary Stent System in the Treatment of Subjects With Ischemic Heart Disease Caused by De Novo Native Coronary Artery Lesions [ABSORB II]; NCT01425281).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Creatina Quinase Forma MB/sangue , Stents Farmacológicos , Everolimo/administração & dosagem , Metais , Infarto do Miocárdio/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Troponina/sangue , Idoso , Biomarcadores/sangue , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Europa (Continente) , Feminino , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Nova Zelândia , Razão de Chances , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima
13.
Heart Lung Circ ; 24(9): 869-78, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25900522

RESUMO

BACKGROUND: Many patients provisionally diagnosed with acute myocardial infarction (AMI) have angiographically unobstructed coronary arteries. Despite other potential causes, patients are often diagnosed as AMI with psychosocial implications and medication burden. The aim of this audit was to review such patients at our centre. METHODS: All patients investigated for possible AMI with coronary angiography from 2007 until 2011 at Christchurch Hospital, New Zealand, in whom cardiac troponin was elevated (with no other cause found for that elevation) but coronary angiography showed diameter stenosis <50% were reviewed. Primary outcome was two-year cardiac death and AMI (by universal definition). RESULTS: Of the 351/6493 (5.4%) who met the inclusion criteria, 180 had normal angiograms and 171 had non-obstructive coronary disease (stenosis >0% and <50%). By two years there were two cardiac deaths (0.6%) and five AMIs (1.4%). The primary outcome rate was therefore 2.0% (2.2% for those with normal angiograms and 1.8% with non-flow limiting coronary disease, p=1.000). CONCLUSION: Patients who have presented with AMI symptoms, elevated cardiac troponin, and unobstructed coronary arteries on angiography are at very low risk of cardiac death (0.6%), AMI (1.4%) or either (2.0%) at two-year follow-up.


Assuntos
Síndrome Coronariana Aguda , Angiografia Coronária , Doença das Coronárias , Troponina/sangue , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Adulto , Idoso , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Doença das Coronárias/patologia , Doença das Coronárias/terapia , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Nova Zelândia
14.
EuroIntervention ; 11(7): 746-56, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25308301

RESUMO

AIMS: To evaluate the implications of an Absorb bioresorbable vascular scaffold (Absorb BVS) on the morphology of the superficial plaques. METHODS AND RESULTS: Forty-six patients who underwent Absorb BVS implantation and 20 patients implanted with bare metal stents (BMS) who had serial optical coherence tomographic examination at baseline and follow-up were included in this analysis. The thin-capped fibroatheromas (TCFA) were identified in the device implantation regions and in the adjacent native coronary segments. Within all regions, circumferential locations of TCFA and calcific tissues were identified, and the neointimal thickness was measured at follow-up. At six to 12-month follow-up, only 8% of the TCFA detected at baseline were still present in the Absorb BVS and 27% in the BMS implantation segment (p=0.231). Sixty percent of the TCFA in native segments did not change their phenotype at follow-up. At short-term follow-up, significant reduction in the lumen area of the BMS was noted, which was higher compared to that reported in the Absorb BVS group (-2.11±1.97 mm2 vs. -1.34±0.99 mm2, p=0.026). In Absorb BVS, neointima tissue continued to develop at midterm follow-up (2.17±0.48 mm2 vs. 1.38±0.52 mm2, p<0.0001) and covered the underlying tissues without compromising the luminal dimensions (5.93±1.49 mm2 vs. 6.14±1.49 mm2, p=0.571) as it was accommodated by the expanded scaffold (8.28±1.74 mm2 vs. 7.67±1.28 mm2, p<0.0001). CONCLUSIONS: Neointimal tissue develops following either Absorb BVS or BMS implantation and shields lipid tissues. The neointimal response in the BMS causes a higher reduction of luminal dimensions compared to the Absorb BVS. Thus, Absorb BVS may have a value in the invasive re-capping of high-risk plaques.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Neointima , Intervenção Coronária Percutânea/instrumentação , Placa Aterosclerótica , Tomografia de Coerência Óptica , Idoso , Ensaios Clínicos como Assunto , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Feminino , Fibrose , Seguimentos , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Fenótipo , Valor Preditivo dos Testes , Desenho de Prótese , Stents , Fatores de Tempo , Resultado do Tratamento
15.
EuroIntervention ; 10(11): 1299-306, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24769420

RESUMO

AIMS: To investigate the extent and the circumferential distribution of the neointima tissue developed following an Absorb bioresorbable vascular scaffold (BVS) implantation. METHODS AND RESULTS: Twenty-three patients who were treated with the Absorb BVS and had optical coherence tomographic examination after scaffold implantation, at six-month and at two-year follow-up, were included in the current analysis. The lumen and the scaffold borders were detected and the circumferential thickness of the neointima was measured at one degree intervals. The symmetry of the neointima was defined as: minimum/maximum thickness. The lumen area was decreased at six months compared to baseline but it did not change between six-month and two-year follow-up (baseline: 7.49 [6.13-8.00] mm², six months: 6.31 (4.75-7.06) mm², two years: 6.01 [4.67-7.11] mm², p=0.373). However, the mean neointima thickness (six months: 189 [173-229] m, two years: 258 [222-283] m, p<0.0001) and the symmetry index of the neointima (six months: 0.06 [0.02-0.09], two years: 0.27 [0.24-0.36], p<0.0001) were increased at two years. Full circumferential coverage of the vessel wall by neointima tissue was seen in 91% of the studied frames at two years. CONCLUSIONS: This study demonstrates that after an Absorb BVS implantation neointima tissue develops that covers almost the whole circumference of the vessel wall. In contrast to the metallic stents, the neointima tissue does not compromise the luminal dimensions. Further research is required to evaluate the neointimal characteristics and assess the potential value of the device in passivating high-risk plaques.


Assuntos
Implantes Absorvíveis , Antineoplásicos/uso terapêutico , Estenose Coronária/cirurgia , Stents Farmacológicos , Neointima/diagnóstico , Sirolimo/uso terapêutico , Alicerces Teciduais , Adulto , Idoso , Estudos de Coortes , Estenose Coronária/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/patologia , Intervenção Coronária Percutânea/instrumentação , Estudos Prospectivos , Tomografia de Coerência Óptica
16.
JACC Cardiovasc Interv ; 7(12): 1400-11, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25523532

RESUMO

OBJECTIVES: This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND: Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS: The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS: Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS: Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents Farmacológicos , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico , Everolimo , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
17.
N Z Med J ; 127(1388): 71-5, 2014 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-24481390

RESUMO

We present an unusual case of congestion bleeding of the head and neck following myocardial infarction. A 51-year-old man presented with widespread facial petechiae and subconjunctival haemorrhages following a collapse associated with evolving electrocardiographic changes. Emergency coronary artery stent placement was undertaken. No cardiopulmonary resuscitation (CPR) was performed. We hypothesise that the presence of facial petechiae in our case following transient loss of consciousness due to a presumed ventricular arrhythmia in the setting of acute myocardial ischaemia, may have been precipitated by a Valsalva manoeuvre on regaining consciousness with sudden acute increase in venous pressure and consequent venous congestion of the head and neck, and that congestion bleeding of the face may occur in acute cardiac events without a history of CPR.


Assuntos
Doenças da Túnica Conjuntiva/etiologia , Hemorragia Ocular/etiologia , Hiperemia/etiologia , Infarto do Miocárdio/complicações , Stents , Angioplastia Coronária com Balão/métodos , Doenças da Túnica Conjuntiva/fisiopatologia , Angiografia Coronária/métodos , Eletrocardiografia/métodos , Tratamento de Emergência , Hemorragia Ocular/fisiopatologia , Face , Seguimentos , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Pescoço , Púrpura/etiologia , Púrpura/fisiopatologia , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
18.
EuroIntervention ; 9(11): 1271-84, 2014 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-24291783

RESUMO

AIMS: To assess observations with multimodality imaging of the Absorb bioresorbable everolimus-eluting vascular scaffold performed in two consecutive cohorts of patients who were serially investigated either at 6 and 24 months or at 12 and 36 months. METHODS AND RESULTS: In the ABSORB multicentre single-arm trial, 45 patients (cohort B1) and 56 patients (cohort B2) underwent serial invasive imaging, specifically quantitative coronary angiography (QCA), intravascular ultrasound (IVUS), radiofrequency backscattering (IVUS-VH) and optical coherence tomography (OCT). Between one and three years, late luminal loss remained unchanged (6 months: 0.19 mm, 1 year: 0.27 mm, 2 years: 0.27 mm, 3 years: 0.29 mm) and the in-segment angiographic restenosis rate for the entire cohort B (n=101) at three years was 6%. On IVUS, mean lumen, scaffold, plaque and vessel area showed enlargement up to two years. Mean lumen and scaffold area remained stable between two and three years whereas significant reduction in plaque behind the struts occurred with a trend toward adaptive restrictive remodelling of EEM. Hyperechogenicity of the vessel wall, a surrogate of the bioresorption process, decreased from 23.1% to 10.4% with a reduction of radiofrequency backscattering for dense calcium and necrotic core. At three years, the count of strut cores detected on OCT increased significantly, probably reflecting the dismantling of the scaffold; 98% of struts were covered. In the entire cohort B (n=101), the three-year major adverse cardiac event rate was 10.0% without any scaffold thrombosis. CONCLUSIONS: The current investigation demonstrated the dynamics of vessel wall changes after implantation of a bioresorbable scaffold, resulting at three years in stable luminal dimensions, a low restenosis rate and a low clinical major adverse cardiac events rate. CLINICAL TRIAL REGISTRATION INFORMATION: http://www.clinicaltrials.gov/ct2/show/NCT00856856.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Stents Farmacológicos , Imagem Multimodal/métodos , Sirolimo/análogos & derivados , Alicerces Teciduais , Angiografia Coronária , Everolimo , Humanos , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção
19.
EuroIntervention ; 9(5): 573-81, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24058075

RESUMO

AIMS: To report the three-year clinical outcome of the Axxess™ stent, a nitinol self-expanding Biolimus A9™ eluting stent for treatment of de novo coronary bifurcation lesions. The Axxess stent is a new-generation drug-eluting stent that might offer advantages in terms of improved clinical outcomes and safety profile in bifurcation lesion stenting. METHODS AND RESULTS: The DIVERGE study was a multicentre, prospective, single-arm trial. The primary endpoint was the cumulative rate of major adverse cardiac events (MACE), a composite of all-cause death, myocardial infarction (MI), and ischaemia-driven target lesion revascularisation (TLR) at one, two and three years. Secondary safety endpoints were cumulative stent thrombosis (ST). A total of 302 patients were included across 14 sites: 77.4% had a true bifurcation lesion, with the left anterior descending/diagonal as target vessel in 80.8%. The Axxess stent was placed in 299 patients (99.0%) and scored as optimal in 93.0%. Two hundred and ninety-eight patients (98.7%) returned for the three-year follow-up. The MACE rate was 9.3% at one year, 14.0% at two years and 16.1% at three years. Individual components at three years were 10.1% for ischaemia-driven TLR, 3.0% for death (2.0% cardiac death), and 7.4% for MI. In the secondary safety endpoint at three years, a total of seven patients (2.3%) had ST with six (2.0%) definite and two (0.7%) probable ST events. CONCLUSIONS: The present large study of the Axxess stent reports a good cumulative MACE rate during three years of long-term follow-up. The Axxess stent offers a promising treatment strategy for bifurcation lesions.


Assuntos
Doença da Artéria Coronariana/terapia , Trombose Coronária/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Idoso , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sirolimo/uso terapêutico , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...